Radwave Electromagnetic Tracking

澳洲8手机软件

Control unit
Antenna
SDK / API
Customization

澳洲8开奖人工计划

EM sensors
EM surgical tools
Manufacturing & assembly
Customization

澳洲8在线走势图

TT Electronics has partnered with Radwave Technologies to help bring an accurate, reliable, and customisable electromagnetic (EM) tracking platform to the surgical navigation market.

  • Real-time motion tracking when there's no line of sight
  • No harmful radiation to patient or staff
  • Accurate, reliable, and low cost
  • Seamless integration into new and existing medical devices and the clinical environment

澳洲8软件下载

Cardiology & Electrophysiology

Cardiology & Electrophysiology

Ear, Nose & Throat

Ear, Nose & Throat

Endoscopy

Endoscopy

Imaging, Navigation, Monitoring

Imaging, Navigation, Monitoring

Neurosurgery

Neurosurgery

Robotic Assisted Surgery

Robotic Assisted Surgery

Spine & Orthopedics

Spine & Orthopedics

澳洲8在线投注

澳洲8几点开始

澳洲8现场开奖视频

澳洲8开奖软件

Designed from the ground up to meet the needs of advanced minimally-invasive surgical (MIS) procedures. Accurate, reliable, and customisable to meet all your procedural needs.

Top Features:

  • Seamless integration into MIS and robotic procedures
  • Accurate and reliable with high sampling rates
  • Translucent antenna during fluoroscopy with uncompromised image quality
  • Able to track many different sizes and types of sensors
  • Customisable sensing volume that can grow or shrink to match the procedure’s needs
  • Rapid integration using encrypted, modern API with open-source SDK

澳洲8官方开奖

澳洲8人工计划网

澳洲8玩法

TT’s sensor technologies deliver the highest degree of accuracy and precision, even in challenging settings where other EM systems have been limited by interference or sensing volume constraints. We have sensors in both 5 degrees of freedom and 6 degrees of freedom configurations. TT’s sensor technologies are easily integrated into a variety of interventional and minimally invasive devices.

TT Electronics is ISO 13485 certified and offers FDA registered and clean room manufacturing facilities. Our clean room facilities are flexible and expandable. They can be configured to meet the specific needs of each unique project with maximum efficiency.

澳洲8官方开奖结果

澳洲8基本走势图

澳洲8人工计划公式

Field Generator / Antenna

Thin, light, radiotranslucent polycarbonate antenna designed for intraoperative fluoroscopy or CT scan.

RWAP1-01

Standard Antenna Placement: between the patient & the table, below the table, or integrated with the table.
Size: 2.2 x 61.0 x 45.8cm (height, length, width)
Weight: 5.20 kg
Sensing Volume: Starting at 40 cm x 50 cm x 45 cm (W x L x H)

澳洲8官方开奖号码

Control Unit

RWCU-01

Size: 1U rack mountable unit (4.5cm x 33.0cm x 40.6cm)
Optional mounting brackets
5x three-coil sensor port connectors
1x nine-coil sensor port connector
1x antenna pad connector
A/C power Ethernet interface with modern & encrypted TCP/IP connection
Sampling rates: Over 100 Hz with 24 sensors
Weight: 3.20 kg

澳洲8网上

019-9388-00R

019-9388-00R
Sensor OD (mm) Max: 0.47
Sensor Length (mm) Max: 5

019-9388-01R

019-9388-01R
Sensor OD (mm) Max: 0.33
Sensor Length (mm) Max: 4.3

019-9388-02R

019-9388-02R
Sensor OD (mm) Max: 0.33
Sensor Length (mm) Max: 3.8

019-9388-03R

019-9388-03R
Sensor OD (mm) Max: 0.48
Sensor Length (mm) Max: 8

019-9388-03R

019-9352-00R (RWSEN2001)
Sensor OD (mm) Max: 0.41
Sensor Length (mm) Max: 4

019-9389-XXR

019-9389-XXR
Sensor OD (mm) Max: Varies
Sensor Length (mm) Max: Varies

 

Single straight coil of ID 3 French and above. Sensor OD and Sensor Length are configurable with the use of different toolings.

澳洲8开奖走势

019-9388-00R

019-9391-00R
Sensor OD (mm) Max: 0.94
Sensor Length (mm) Max: 9.7

019-9388-01R

019-9354-00R (RWSEN2004)
Sensor OD (mm) Max: 1.25
Sensor Length (mm) Max: 3

019-9388-02R

019-9390-XXR
Sensor OD (mm) Max: Varies
Sensor Length (mm) Max: Varies

 

Dual angular wound coil of ID 3 French and above. Sensor OD and Sensor Length are configurable with the use of different toolings.

FDA
ISO 13485
SG赛车下载 极速飞艇计划全天 澳洲10官方直播 极速赛车五码计划两期 澳洲幸运5直播 澳洲8开奖结果时间 SG飞艇历史开奖号码 澳洲幸运10官方开奖直播